Acta Chimica Sinica ›› 1994, Vol. 52 ›› Issue (1): 83-88. Previous Articles     Next Articles

Original Articles

流动注射化学发光免疫分析研究I. 血清中乙型肝炎表面抗原的测定

张新荣;封满良;吕九如;章竹君   

  1. 陕西师范大学化学系
  • 发布日期:1994-01-15

Studies on flow injection chemiluminescence immunoassay I. determination of HBsAg in serum

ZHANG XINRONG;FENG MANLIANG;LU JIURU;ZHANG ZHUJUN   

  • Published:1994-01-15

In this paper, a new immunoassay technique, flow Chemiluminescence injection immunoassay, in which controlleld pore glass immobilized with antibody was used as immunoreactor and chemiluminescence for end-point monitoring, has been developed. Researches show that the time required per assay only 20 min with this method while 20h with conventional ELISA. Moreover, the whole assay can been taken automatically under the control of a microprocessor. This technique has been used for the determination of HBsAg in serum, and the results are comparable with that of ELISA. In addition, it has a relative standard deviation of 7.2%(9 assays). So this technique offers advantages of automatically rapidly and stablity.

Key words: HEPATITIS, SERUM, FLOW INJECTION ANALYSIS, CHEMILUMINESSENCE, SURFACE ANTIGENS

CLC Number: