Acta Chimica Sinica ›› 2005, Vol. 63 ›› Issue (14): 1313-1317. Previous Articles     Next Articles

Original Articles

纳米二氧化锡电极的制备及其用于水体中大肠杆菌的快速计数研究

张文,唐辉,顾静,耿萍,金利通*   

  1. (华东师范大学化学系 上海 200062)
  • 投稿日期:2004-12-17 修回日期:2005-03-18 发布日期:2010-12-10
  • 通讯作者: 金利通

Study on Preparation of Nano-SnO2 Electrode and Its Application to the Fast Counting of E. coli in Water

ZHANG Wen, TANG Hui, GU Jing, GENG Ping, JIN Li-Tong*   

  1. (Department of Chemistry, East China Normal University, Shanghai 200062)
  • Received:2004-12-17 Revised:2005-03-18 Published:2010-12-10

A novel nano-SnO2 electrode was fabricated and applied to the fast counting of E. coli in water. The nano-SnO2 electrode was used as bioelectrochemical sensor in chronoamperometry to count fastly E. coli with the advantages of quickness, simple operation and high sensitivity. Through assaying the MDA content of E. coli solution treated by electrochemical oxidation, the oxidation mechanism of E. coli at nano- SnO2 electrode was investgated and satisfactory results were obtained.