A method has been established for coulometric-complexometric titration of microgram quantities of zirconium with high selectivity.At pH 1.5-1.8 zirconium can displace the ferric ion from the Fe3+-EDTA complex.Then the released ferric ion was titrated with the electrogenerated Fe2+-EDTA from Fe3+-EDTA and a current density 135μA/cm2.The end point was detected spectrophotometrically with sulfosalicylic acid as indicator.Many metal ions, excopt bismuth (Ⅲ),did not interfere.The relative error is 0.1-0.5% for 3.6-45μg of zirconium.
MO JIN-YUAN, LIN ZHI-QING. COULOMETRIC-COMPLEXOMETRIC TITRATION Ⅱ. COULOMETRIC-COMPLEXOMETRIC TITRATION OF MICRO AMOUNTS OF ZIRCONIUM[J]. Acta Chimica Sinica, 1980, 38(4): 387-391.