Article

An Approach for Irreversible Bonding of PDMS-PS Hybrid Microfluidic Chips at Room Temperature

  • Hu Xianqiao ,
  • He Qiaohong ,
  • Bai Zeqing ,
  • Su Faming ,
  • Chen Hengwu
Expand
  • Department of Chemistry, Institute of Microanalytical Systems, Zhejiang University, Zijin'gang Campus, Hangzhou 310058

Received date: 2013-06-28

  Online published: 2013-08-12

Supported by

Project supported by the National Basic Research Program of China (973 Program, No. 2007CB714502) and the National Natural Science Foundation of China (No. 20890020).

Abstract

In some circumstances, hybrid polymer microfluidic chips composed of both elastic, gas-permeable polydimethylsiloxane (PDMS) and rigid plastics are needed. However, it is quite difficult to bond PDMS irreversibly to plastics such as polystyrene (PS). In this article, a facile method for irreversible bonding of PDMS to PS was proposed based on UV/O3-assisted surface modification in combination of surface silanization. Firstly, a PS sheet was exposed to UV/O3 to produce oxygen-containing polar moieties, such as hydroxyl and carboxylic acid, on its surface. Secondly, the UV/O3 treated PS sheet was silanized with (3-aminopropyl)triethoxysilane (APTES) via the reaction between the oxygen-containing polar moieties on the PS surface and the molecules of APTES. Thirdly, the silanized-PS sheet and the PDMS substrate with micro channel network were treated with UV/O3 again to generate silanol moieties on both surfaces. Finally, the UV/O3 treated PDMS was immediately brought intimate contact with the UV/O3 treated silanized-PS, and irreversible bonding of PDMS with PS occurred after putting the PDMS-PS complex at room temperature for 1 h through the condensation reaction between silanol moieties. Contact angle measurement, X-ray photoelectron spectroscopy, total reflection Fourier transformation infrared spectrometer were applied to characterize the surface chemistry of the PS during the UV/O3 treatment and silanization. The hybrid PDMS-PS microfludic chips prepared with the established method can bear a gas pressure higher than 0.5 MPa and a water stream at a flow rate higher than 170 μL/min (the test channels were 2.5 cm in the length, 50 μm in the width, 200 μm in the depth). A hybrid PDMS-PS microfluidic chip composed of gas-permeable PDMS substrate with channel network and excellently biocompatible PS cover sheet was fabricated for cell culture. The experimental results showed that HeLa cells cultured in the hybrid PDMS-PS microchip grew much better than those cultured in the full PS microchip, and slightly better than those in the full PDMS microchip.

Cite this article

Hu Xianqiao , He Qiaohong , Bai Zeqing , Su Faming , Chen Hengwu . An Approach for Irreversible Bonding of PDMS-PS Hybrid Microfluidic Chips at Room Temperature[J]. Acta Chimica Sinica, 2013 , 71(11) : 1535 -1539 . DOI: 10.6023/A13060678

References

[1] Alrifaiy, A.; Lindahl, O. A.; Ramser, K. Polymers 2012, 4, 1349.
[2] Li, J. J.; Chen, Q.; Li, G.; Zhu, Z. Q.; Zhao, J. L. Acta Chim. Sinica 2009, 67, 1503. (李俊君, 陈强, 李刚, 朱自强, 赵建龙, 化学学报, 2009, 67, 1503.)
[3] Kim, L.; Toh, Y. C.; Voldman, J.; Yu, H. Lab Chip 2007, 7, 681.
[4] Vlachopoulou, M. E.; Tserepi, A.; Pavli, P.; Argitis, P.; Sanopoulou, M.; Misiakos, K. J. Micromech. Microeng. 2009, 19, 015007.
[5] Tang, L.; Lee, N. Y. Lab Chip 2010, 10, 1274.
[6] Bai, Z. Q.; He, Q. H.; Huang, S. S.; Hu, X. Q.; Chen, H. W. Anal. Chim. Acta 2013, 767, 97.
[7] Hu, X. Q.; Jiang, Y.; He, Q. H.; Shi, Y. M.; Hu, C. C.; Tang, N.; Chen, H. W. Acta Chim. Sinica 2012, 70, 2144. (胡贤巧, 蒋艳, 何巧红, 施秧梦, 胡辰辰, 汤凝, 陈恒武, 化学学报, 2012, 70, 2144.)
[8] Xu, B. Y.; Yan, X. N.; Xu, J. J.; Chen, H. Y. Biomicrofluidics 2012, 6, 016507.
[9] Duffy, D. C.; McDonald, J. C.; Schueller, O. J. A.; Whitesides, G. M. Anal. Chem. 1998, 70, 4974.
[10] Zhang, W. H.; Lin, S. C.; Wang, C. M.; Hu, J.; Li, C.; Zhuang, Z. X.; Zhou, Y. L.; Mathies, R. A.; Yang, C. Y. J. Lab Chip 2009, 9, 3088.
[11] McDonald, J. C.; Duffy, D. C.; Anderson, J. R.; Chiu, D. T.; Wu, H. K.; Schueller, O. J. A.; Whitesides, G. M. Electrophoresis 2000, 21, 27.
[12] Meng, F.; Chen, H. W.; Fang, Q.; Zhu, H. L.; Fang, Z. L. Chem. J. Chin. Univ. 2002, 23, 1264. (孟斐, 陈恒武, 方群, 朱海霖, 方肇伦, 高等学校化学学报, 2002, 23, 1264.)
[13] Hu, X. Q.; He, Q. H.; Lu, H.; Chen, H. W. J. Electroanal. Chem. 2010, 638, 21.
[14] Dulcey, C. S.; Georger, J. H.; Krauthamer, V.; Stenger, D. A.; Fare, T. L.; Calvert, J. M. Science 1991, 252, 551.
[15] Ye, T.; McArthur, E. A.; Borguet, E. J. Phys. Chem. B 2005, 109, 9927.
[16] Ma, D.; Chen, H. W.; Li, Z. M.; He, Q. H. Biomicrofluidics 2010, 4, 044107.
[17] Ziolkowska, K.; Kwapiszewski, R.; Brzozka, Z. New J. Chem. 2011, 35, 979.
Outlines

/