化学学报 ›› 2013, Vol. 71 ›› Issue (01): 62-68.DOI: 10.6023/A12100742 上一篇    下一篇

研究论文

动态磁涂覆混合纳米固定相毛细管电色谱中芳香酸的输运特征研究

张凌怡, 朱亚仙, 张维冰   

  1. 华东理工大学 上海市功能性材料化学重点实验室 上海 200237
  • 投稿日期:2012-10-13 发布日期:2012-12-10
  • 通讯作者: 张维冰 E-mail:weibingzhang@ecust.edu.cn
  • 基金资助:
    项目受国家自然科学基金(No. 21075039)、教育部(No. 20100074110016)和中央高校基金科研业务费专项资金(No. WK1014042)资助.

Transport Characteristics of Aromatic Acids in the Capillary Electrochromatography with Mixed Magnetic Nanoparticles Coating as Stationary Phase

Zhang Lingyi, Zhu Yaxian, Zhang Weibing   

  1. Shanghai Key Lab of Functional Materials Chemistry, East China University of Science and Technology, Shanghai 200237
  • Received:2012-10-13 Published:2012-12-10
  • Supported by:
    Project supported by the National Natural Science Foundation of China (No. 21075039), the Specialized Research Fund for the Doctoral Program of Higher Education of China (No. 20100074110016) and the Fundamental Research Funds for the Central Universities (No. WK1014042).

推导了芳香酸在动态磁涂覆混合纳米固定相开管毛细管柱中等度洗脱和二元台阶梯度洗脱条件下的输运方程, 考察了其在该色谱柱上的保留特征. 结果表明, 等度洗脱时, 电渗流方向及大小随着两种固定相配比的改变而改变, 溶质的容量因子与弱阴离子交换固定相和反相固定相比例(Fe3O4@SiO2-NH2︰Fe3O4@SiO2-C18)之间具有良好的线性关系, 拟合后相关系数大于0.9166. 二元台阶梯度洗脱条件下, 溶质的迁移时间可以通过其在等度洗脱条件下的洗脱时间加以预测. 溶质在经磷酸缓冲液浓度、有机调节剂浓度和pH值台阶梯度洗脱后, 其预测保留时间和实际保留时间之间的相对误差分别小于8.0%, 10%和5.8%. 构建的系统在优化的色谱条件下对水提天麻进行了分离, 其主要成分柠檬酸的保留时间预测值与实际值之间相对误差为11%.

关键词: 梯度洗脱, 输运特征, 混合固定相

In this paper, novel open-tubular electrochromatographic system with core/shell magnetic nanoparticles modified by amino and C18 functional groups as mixed stationary phase by using a series of permanent magnets to immobilize nanoparticles into the capillary were investigated. The new system showed high separation ability and efficiency due to high specific surface area of nanomaterial and mixing separation mechanism. The transport equations of aromatic acids using the open-tubular electrochromatographic column with magnetic nanoparticle coating as stationary phases were derived under isocratic and double stepwise gradient elutions, and the retention characteristics of organic acids separated by the columns were further investigated. The results showed that the electroosmotic flow gradually decreased with the increase of Fe3O4@SiO2-NH2 in the mixed stationary phases, and the direction of electroosmotic flow reversed eventually. The capacity factor was relevant to the ratio of ion-exchange and reversed-phase stationary phases. Furthermore, experiments confirmed that the capacity factor of solute had a good linear relationship with the ratio of mixed stationary phases, and the correlation coefficient was greater than 0.9166 after fitting. Under the double stepwise gradient elution condition, the migration time of solute can be predicted by its elution time under isocratic elution. After the solutes were eluted by phosphate buffer stepwise gradient elution, the relative errors between predicted retention time and actual retention time of solute were less than 8.0%. After they were eluted by organic modifier concentration stepwise gradient elution, the relative errors between two values of solute were less than 10%. After they were eluted by pH value stepwise gradient elution, the relative errors between two values of solute were less than 5.8%. Rhizoma gastrodiae was separated by the constructed system under the optimized chromatographic condition, the main components of gastrodin, vanilla alcohol and citric acid were identified based on retention time of standards, and the relative errors between predicted value and actual value of citric acid was 11%. The open-tubular electrochromatographic system shows great potential in the method development of analysis of complicated samples.

Key words: gradient elution, transport characteristic, mixed stationary phase