测定铁、钴混合液中数微克的铁(钨已事先用化学方法除去),如铁钴之比为1:10或以下,可毋须分离,进行比色测定。如铁钴之比为1:50至1:3000,则用纸层析后再比色测定,结果良好(相对误差为0.3—3%)。溶液中如尚含其他化合物及滤纸之品质均对层析分离有影响。

Estimation of contaminated iron in tungsten-cobalt alloy can be performed with the aid of paper-descending chromatographic method. After the alloy has been fused with sodium carbonate in a platinum crucible, tungsten is removed by precipitation. In the filtrate, iron and cobalt are separated by means of paper chromatography. Cut out the portion of paper strip which contains only iron and extract with 0.1 N hydrochloric acid. Finally iron is determined colorimetrically.