化学学报 ›› 2009, Vol. 67 ›› Issue (12): 1291-1296. 上一篇    下一篇

研究论文

借助聚丙烯酸制备铜粒子修饰电极并用于双氧水的电催化性能研究

唐艳红*,a,b 曹 宇a 沈国励*,a 俞汝勤a

  

  1. (a湖南大学化学化工学院 化学生物传感与计量学国家重点实验室 长沙410082)
    (b湖南大学材料科学与工程学院 长沙410082)

  • 投稿日期:2008-10-18 修回日期:2008-12-15 发布日期:2009-06-28
  • 通讯作者: 唐艳红

Preparation of Copper Particles on a Poly(acrylic acid)-deposited Electrode for Electrocatalysis of Hydrogen Peroxide

Tang, Yanhong *,a,b Cao, Yu a Shen, Guoli *,a Yu, Ruqin a   

  1. (a State Key Laboratory of Chemo/Biosensing and Chemometrics, Chemistry and Chemical Engineering College,
    Hunan University, Changsha 410082)
    (b College of Materials Science and Engineering, Hunan University, Changsha 410082)
  • Received:2008-10-18 Revised:2008-12-15 Published:2009-06-28
  • Contact: Tang, Yanhong

利用羧基对金属离子的络合作用在电极表面原位制备金属粒子用于电催化过氧化氢(H2O2). 首先在电极表面电沉积聚丙烯酸, 然后化学吸附铜离子, 再用水合肼将其还原成零价铜. 铜粒子簇均匀分散在聚丙烯酸网络中, 其尺寸可通过吸附铜离子的数量和吸附-还原次数来控制. 由于铜微粒的电催化作用, 该修饰电极对H2O2表现出了良好的电流响应. 运用该方法可以在电极表面制备多种金属微粒, 并且聚丙烯酸的自由羧基可以与氨基反应, 从而可共价固定带氨基的酶和抗体, 有望构建多种新型的化学和生物传感器.

关键词: 金属粒子, 原位制备, 聚丙烯酸, 双氧水, 生物传感器

The complexation of carboxyl groups to metal ions was exploited to in situ prepare metal particles on the electrode surface for electrocatalysis of hydrogen peroxide (H2O2). Poly(acrylic acid) (PAA) was first electrodeposited onto a gold electrode. Then copper ions were chemically adsorbed within the PAA network, and subsequently reduced by hydrazine hydrate to yield zerovalent copper. The resultant Cu clusters were uniformly dispersed in the PAA network and their size and density could be easily controlled through controlling the amount of copper ions in the film and the loading-reduction cycles. Thus modified electrode showed good current response to H2O2 due to the catalytic activity of copper particles. Various metal catalysts can be prepared on the electrode surface by the same method. Moreover, PAA can covalently immobilize enzyme and antibody by bonding between amino groups of the biomolecules and free carboxyl groups of PAA, therefore, a variety of new chemo- and bio-sensors could be constructed.

Key words: metal particle, in situ preparation, poly(acrylic acid), H2O2, biosensor