Acta Chimica Sinica ›› 2002, Vol. 60 ›› Issue (7): 1269-1273. Previous Articles     Next Articles

Original Articles

血红蛋白在磷脂-月桂酸修饰的玻碳电极上的电化学行为及其分析应用

金松子;王韬;张春煦;沈含熙   

  1. 南开大学化学学院.天津(300071)
  • 发布日期:2002-07-15

Electrochemical Behavior of Hemoglobin at a Lipid-Lauric Acid Modified GC Electrode and Its Application to the Determination of Proteins

Jin Songzi;Wang Tao;Zhang Chunxu;Shen Hanxi   

  1. Chemical School, Nankai University.Tianjin(300071)
  • Published:2002-07-15

The electrochemical behavior of hemoglobin at a lipid-lauric acid modified glassy carbon electrode (GC) is reported. In the potential range of +0.8~-0.7 V (vs. Ag/AgCl), an irreversible cathodic peak was observed at -0.4 V at the scan rate of 20 mV/s. In the medium of 0.01 mol/L KH_2PO_4-Na_2HPO_4 (pH 6.0), the cathodic peak current shows linear relationship with the concentration of hemoglobin in the range of 1.25 * 10~(-8)~4.31 * 10~(-7) mol/L. The electrode can be used as an approach for determining hemoglobin with high sensitivity.

Key words: HEMOGLOBIN, LIPID MEMBRANE, PHOSPHOLIPID, LAURIC ACID, GLASSY CARBON ELECTRODE, CHEMICAL MODIFIED ELECTRODE

CLC Number: