Acta Chimica Sinica ›› 1997, Vol. 55 ›› Issue (6): 590-594. Previous Articles     Next Articles

Original Articles

流动注射化学发光免疫分析研究II. 偶合反应测定HRP及其标记 物

邵谦;马望百;封满良;章竹君   

  1. 陕西师范大学化学系.西安(710062)
  • 发布日期:1997-06-15

Studies on flow-injection chemiluminescence immunoassay II. Determination of HRP and its conjugates with coupled reaction

Shao Qian;Ma Wangbai;Feng Manliang;Zhang Zhujun   

  1. Shanxi Normal Univ, Dept Chem.Xian(710062)
  • Published:1997-06-15

In this paper chitoson, controlled pore glass and silica-gel have been investigated with respect to its potentiality of being used as solid support of flow-injection immunoassay. A new flow-injection immunoassay end-point detection method has also been developed on the basis of coupling the reaction of H~2O~2 and K~4Fe(CN)~6, catalyzed by HRP, with H~2O~2 and K~3Fe(CN)~6 co-oxidized chemiluminescence reaction of luminol. As enzymatic and chemiluminescent reaction were generated at different sites of the detection system. The general shortcomings of such as unable to select a optimum pH for both enzymatic and chemiluminescent reaction, incomplete contact between enzyme and substrate, and scattering of support have been eliminated. It has the advantages of high sensitivity and good accuracy. HRP and its conjugates at f mol level can be detected within 1-2 min. and the relative standard deviation is 3.9%.

Key words: COUPLING REACTION, CHEMILUMINESSENCE, FLOW INJECTION ANALYSIS, LABELLED COMPOUNDS

CLC Number: